Electric Steam Boiler

Product Details
After-sales Service: 24 Hours
Warranty: One Year
Certification: ISO9001, ISO, CE
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
500000 RMB
Plant Area
501~1000 square meters
  • Electric Steam Boiler
  • Electric Steam Boiler
  • Electric Steam Boiler
  • Electric Steam Boiler
Find Similar Products

Basic Info.

Material Capabilities
Hardened Metals
Type
Accessories
Powder
64kw
Voltage
220V
Electricity
3phase
Transport Package
Wooden
Specification
8 TYPE
Trademark
stonepack
Origin
China

Packaging & Delivery

Package Size
109.00cm * 73.00cm * 151.00cm
Package Gross Weight
185.000kg

Product Description

1. Introduction to the electric steam generator
(1) Electric Heating Steam Generator

It uses electricity as its energy source, is noiseless, 100% pollution-free and harmless, and is a green and environmentally friendly product. For small boilers under 30Kg, the electrical control of the furnace body is integrated, which is convenient for installation and connection, ensuring the stable operation of the electrical control devices. With advanced technology and production processes, the thermal efficiency reaches 98%. Advanced computer boiler controllers are adopted, which are reliable in performance, highly automated and easy to use. Use high-quality electrical components to ensure the service life of the product. An electric heating steam generator is a miniature boiler that automatically and continuously produces high pressure steam, powered by electricity, noise -free and pollution-free. It uses high-quality heating tubes, has a low surface heat load, high thermal efficiency, and is easy to install and maintain. It can provide the necessary dry steam for industrial steam irons and steam ironing machines. According to the Pot Code, a water capacity of less than 30Kg or a pressure of 0.09MPa or less does not require installation notification and supervision inspection

(2)Working Principle Of The Electric
Steam Generator

The electric steam generator mainly consists of the water supply system, the automatic control system, the furnace and heating system, and the safety protection system, etc. The basic working principle is: through a set of automatic control devices, it ensures that the liquid control or high, medium, and low electrode probe feedback controls the opening and closing of the water pump during operation; The maximum steam pressure is set by the pressure controller. As steam is continuously output, the water level in the furnace keeps dropping. When it is at the low or medium water level, the water pump automatically replenishes water. When it reaches the high water level, the water pump stops replenishing water. At the same time, the electric heating tubes in the furnace continue to heat up and generate steam continuously, and the pointer pressure gauge at the top shows the steam pressure value immediately, and the entire process can be automatically displayed by the indicator light.

(3)The Function Of The Electric 
Steam Generator

1. Abnormal power protection function of the electric steam generator: The boiler stops running immediately. 2. Electric steam generator leakage protection function: The control system will automatically cut off the power supply when it detects leakage of the electric heating element. 3. Electric steam generator water shortage protection: When the boiler is short of water, the control circuit of the heating tube is cut off in time to prevent the heating tube from being damaged by dry burning, and at the same time the controller issues a water shortage alarm indication. 4. Electric steam generator power supply anomaly protection function: The boiler stops running immediately.

(4)Feature Of The Electric Steam Generator

1. The electric steam generator adopts advanced electric heating tubes, which have a low surface load and a long service life
2. The electric steam generator boiler starts and stops quickly, the operating load adjustment range is wide, the adjustment speed is fast, and the operation is simple.
3. The electric steam generator heating element adjusts the number of groups of heating tubes put into operation according to the pressure change, thereby extending the service life of the heating tubes.
4. The heating elements of the electric steam generator can also be manually activated or stopped, allowing users to flexibly adjust the heat output of the boiler.
5. The electric steam generator is equipped with an advanced computerized boiler controller, which has the advantages of reliable performance, high degree of automation and ease of use.
6. The accessories used in the electric steam generator are all high-quality domestic products and have been tested in the furnace to ensure the long-term normal operation of the boiler.

(5) The Purpose Of The Electric Steam Generator

1. The electric steam generator provides steam for food cooking and processing, dyeing and printing, pharmaceuticals, garment ironing, road construction and maintenance, for disinfection in medical institutions, and for other enterprises, institutions, hotels, and bathrooms heated by water tanks to provide domestic hot water.
2. Washing and ironing industry: used in conjunction with dry cleaning machines, dryers, washing machines, dehydrators, ironing machines, irons, etc.
3. Food machinery industry: Tofu machine, steamer, sterilizer, packaging machine, coating equipment, sealing machine, etc.
4. Bio-chemical industry: Fermentation tank, reactor, double-layer pot, mixer, emulsifier,etc
5. Other industries: (oil fields, automobiles) Steam cleaning industry, (hotels, dormitories, schools, mixing plants) Hot water supply, (Bridges, railways) concrete curing, (leisure beauty clubs) sauna and bath, heat exchange equipment, etc
.

2. Introduction to the desigh,production and use of electric steam generator
1. Safety in design, production and use
1 Leakage protection: When leakage occurs in the boiler, the power supply is cut off in time through the leakage circuit breaker to ensure personal safety.
2 Water shortage protection: When the boiler is short of water, the heating tube control circuit is cut off in time to prevent the heating tube from being damaged by dry burning, and at the same time the controller issues a water shortage alarm indication.
3 Grounding protection: When the boiler shell is electrified, the leakage current is conducted to the ground through the grounding wire to ensure personal safety. Usually protect the grounding wire A good metallic connection with the ground is often used, with Angle iron or steel pipe buried deep underground as the grounding body, and the grounding resistance shall not be greater than 4Ω.
4 Steam overpressure protection: When the steam pressure of the boiler exceeds the set upper limit pressure, the safety valve activates and releases steam to reduce the pressure.
5 Overcurrent protection: When the boiler operates under overload (excessively high voltage), the leakage circuit breaker automatically trips.
6 Power protection: With the aid of advanced electronic circuits, reliable power-off protection is provided after detecting fault conditions such as overvoltage, undervoltage, and phase loss.
2. Ease of use
1 After the power is introduced into the electrical control box, with a single button operation, the boiler enters (or disengages) the fully automatic operation state.
2 When the water volume in the boiler decreases, the control system automatically replenishes water from the water tank to the boiler through the make-up water pump.
3. Rationality of the design
In order to use electricity reasonably and effectively, the heating power is specially divided into several segments and automatically cycled on (off) by the controller. After the user determines the heating power according to actual needs, they only need to close the corresponding leakage circuit breaker (or press the corresponding on -off switch). The segmented and cyclic switching of the heating tubes reduces the impact of the boiler on the power grid during operation.
4. Reliability in use
1 The boiler body uses argon arc welding for the base, manual welding for the cover, and has undergone strict X-ray flaw detection.
2 The steel used in the boiler is selected strictly in accordance with the manufacturing standards.
3 The accessories used in the boiler are selected from high-quality domestic and foreign products and have been tested in the furnace to ensure the long-term normal operation of the boiler.
3. Part names and main components of the electric steam generator
1). Part names
2). Description of main components

1 Water level gauge alarm and water level gauge: The water level gauge is a direct observation point for displaying the internal water level of the boiler. The internal water electrode is an important safety accessory for indicating the normal operation of the burner and water pump. Currently, our company commonly uses two types of water level gauges: plate level gauges and black and white level gauges. When there are impurities in the water level gauge that make it difficult to see the water level or affect the water level action, please open the cleaning valve and clean the water level gauge in a timely manner. Attention: The reliability of this simple component largely determines the safe and reliable operation of the boiler.

Electric Steam Boiler

 

Serial Numbers
 
Name

1
Waterlevel gauge body

2
Waterlevel gauge glass

3
Electrode PLUG

4
 
Electrode rod
Integrated water level gauge maintenance and use:
1) Install according to the diagram and keep the water and gas paths unobstructed during use to prevent false water levels.
2) The normal water level in the boiler is between 1/2-3/4 of the water level glass mouth.
3) Rinse the water level gauge after use every day. If there is an abnormal water level, the boiler should be shut down for maintenance.
4) The sealing gasket and sealing bag on the water level gauge may corrode after prolonged use and should be replaced at an appropriate time. 5) If the water pump keeps replenishing water, the installation of the water electrode and grounding should be checked in a timely manner. Serial Numbers Name
1 Waterlevel gauge body
2 Waterlevel gauge glass
3 Electrode PLUG
4 Electrode rod
 2 Pressure controller (pressure switch) Select a pressure controller dedicated to the evaporator, whose performance is as shown below in the figure: where 1 is the moving needle and 3is the high-pressu re needle 5 is the low-pressure needle. When the pressure inside the boiler has not reached the rated steam pressure, 5 will close and the electric heater will be activated When the pressure reaches the rated steam pressure, 1,5 is open, 1,3 is closed, and the electric heater stops Stop working. When adjusting the pressure switch, it should be done within the working pressure range of the boiler and not above the factory level Set, the lower limit must not be lower than 1kg/cm2, otherwise the electric heater will not work. 3 Safety valve Use a micro-lift safety valve for electric steam generation. When the steam pressure exceeds the specified pressure, the safety valve The valve disc opens automatically to release the steam, preventing the pressure from rising further and reducing the pressure inside the furnace